This update can only be installed and used when a full version of EN-Track version 6.26 or 6.29 is prevously installed. It contains an update on the main module,  the language file and the manual and help files (Both English and German manuals!). Especially users of the EN-Motion device are strongly recommended to perform this update.

For new installation on a Windows 7/8/10 system, you have to aquire the full version of EN-Track 6.30 en install from this medium.
Download the file and execute it. If your base version is not v6.26 or v6.29, this update will not be installed.


NOTE:
As of version 6.28 this comes with the new licensing method. After installing one must apply for a new license! This license will then be valid for multiple workstations and needs no renewal !

 

datum title size  
2016-05-13 EN-Track v6 version 6.30.0 update GB 9,5 Mb download  download
2016-05-13 EN-Track v6 version 6.30.0 update D 10,5 Mb download  download
2016-05-13 EN-Track v6 version 6.30.0 update F 9,5 Mb download  download
2016-05-13 EN-Track v6 version 6.30.0 update E 9,5 Mb download  download
2016-05-13 Russian Language update Only
(need EN-Track v6 version v6.29 or v6.30)
24,4 Mb download  download

Chipcard driver for EN-Track system:

 

       
2015-07-31
CC 2700R
Identive uTrust USB Chipcard driver v1.17
(installation file inside ZIP file)

(Windows® , XP x64 [AMD64, EMT64], Vista, Vista x64 [AMD64, EMT64], 7, 7 x64 [AMD64, EMT64], windows 8, Server 2008, Server 2008 x64 [AMD64, EMT64]), Windows 10)
4 Mb download  download
   
2015-03-10
CC SCRxx
SCM SCR 3xx USB Chipcard driver v8.65

(Windows®  XP, XP x64 [AMD64, EMT64], Server 2003, Server 2003 x64 [AMD64, EMT64], Vista, Vista x64 [AMD64, EMT64], 7, 7 x64 [AMD64, EMT64], windows 8, Server 2008, Server 2008 x64 [AMD64, EMT64]), Windows 10)
11.5 Mb download  download
 

List of updates in En-Track version 6.30.0

 
  Functionality improvements:
  • Recovery of data after a system crash, enhanced
  Solved issues:
  • The Grafical display of EN-Motion 6 minute Walking test corrected.
  • Several minor issues are resolved
 

List of updates in En-Track version 6.29.7

 
  Functionality improvements:
  • Added support for EN-Cardio SteepRamp test (selectable via Default Settings)
  • A warning is given when a EN-Cardio VO2 test is written to the CC and no weight is known
  • Option added to automatically set all remaining exercises/series as DONE when read from CC (blue -> green ). This option is selectable in Default Settings. Standard value is OFF.
  • Support van de latest SRC3311 Reader
  Solved issues:
  • The VO2Max/Kg value in the Test Report is corrected (A comma was missing).
  • Import Cliënten function is corrected so it works with a standard Windows 7/8 (64bit) installation.
  • Several minor issues are resolved
 

List of updates in En-Track version 6.29.4

 
  Functionality improvements:
  • Support latest version CC readers
  Solved issues:
  • Issue with McAffee 8.8 and switching from configurator to main EN-Track program solved.
  • In the case of long periods between making, using and reading the CC, sometimes the current-date was wrongly used.
 

List of updates in En-Track version 6.29.2

 
  Functionality improvements:
  • Start speed of EN-Motion hartrate controlled exercises, is set to 2 km/h
 

List of updates in En-Track version 6.29.1

 
  Solved issues:
  • Target Test value was display wrong in graphic screen.
  • Sometimes an Access violation occured after backup was taken. (data is not corrupted but EN-Track had to be restarted)
  List of updates in En-Track version 6.29:  
  Functionality improvements:
  • Client archive function add
  • EN-Track is now Windows 7 32bit/64bit compatible (need full version)
 
  Solved issues:
  • Database Issue concerning EN-Motion data is resolvedsolved.

It is strongly advised to install this version for users of the EN-Motion device
 
 

List of updates in En-Track version 6.28

 
  Functionality improvements:
  • Full support of EN-Motion added
    rem: When using the EN-Motion, in the Configurator both Exercises as Test templates must be added (previously the test templates came automatic with the exercise templates)
 
 

List of updates in En-Track version 6.27.9

 
  Solved issues:
  • Additional rounding problem solved.

It is strongly advised to install this version for all 6.26, 6.27.x users
 
 

List of updates in En-Track version 6.27.8

 
  Functionality improvements:
  • Automatic (on-time) Database backup improved.

Solved issues:
  • Multi-selection of exercises (and tests) addition problem (blue arrow)fixed
  • Shift-S could close the indication window

It is strongly advised to install this version for all 6.26, 6.27.x users
 
 

List of updates in En-Track version 6.27.7

 
  Functionality improvements:
  • Check on DB-available connections improved .
  • DB-recovery improved.

Solved issues:
  • Internet-license extension problem fixed
  • Popup menu and minus- , plus-keyboardbuttons now also controlled by security feature Disabled functions
  • Exercise "arrow" selection button could leave de selection list empty (grey)
  • Panelresize issues resolved (cosmetic)
  • Rounding of force-steps in exercise-edit screen fixed

It is strongly advised to install this version for all 6.26, 6.27.x users
 
 

List of updates in En-Track version 6.27.4

 
  Functionality improvements:
  • Manual and Help files uptodate with current software version (NL and GB only)

Solved issues:
  • Report of Testdata only showed the first testresult

It is strongly advised to install this version for all 6.26, 6.27.x users
 
 

List of updates in En-Track version 6.27.3

 
  Solved issues:
  • Chipcard data was sometimes not read correctly
  • When accessing an exercise directly for viewing or editting (via a double-click in the Indication screen) and there where more then one of the same type, it could happen that the other exercise instance was shown


It is strongly advised to install this version for all 6.26, 6.27.1 and 6.27.2 users
 
 

List of updates in En-Track version 6.27.2

 
  Functionality improvements:
  • Search time in Client mode optimized


It is strongly advised to install this version for all 6.26 users
 
 

List of updates in En-Track version 6.27

 
  Functionality improvements:
  • In Client mode: if an empty or wrongly formatted CC was inserted while the client wanted to create a new card, a message appeared indicating the state of the data on the chipcard. This message is removed.
  • In the exercise information screen, the construction of a target value is better displayed. Also the values can be changed directly with short-keys. (read the hints shown for each component, by keeping the mouse pointer still above it)
  • Now the backup procedure can be automated completely on a specific time of day without closing EN-Track down. If a backup is possible at that moment (e.g. no other EN-Track PC's active) it will be executed and written into a location which can be specified separately.
  • before a backup is started, the possibility is offered to cancel the backup procedure within 5 seconds.

Solved issues:
  • If a chipcard is inserted and the reading process fail for some reason (CC dirty), the next time you want to read the CC, the data was "already read". Now the CC can be inserted again an de data read.
  • In some configurations, reading of chipcard can result in a system hang. This is solved.
  • In clientmode, the screen could be change to a smaller size, and not changed back again.
  • On printing or showing of the graphic result screen, a error message could appear "Out of Index" . This is solved.
  • Mouse wheel action didn't function properly.

It is strongly advised to install this version for all 6.26 users
 
 

List of updates in En-Track version 6.26

 
 
 
Functionality improvements:
  • Administrator rights added. The removal of clients, indications or performed trainings, can be shielded by a password. The same goes for the starting of the configurator. Options can be adjusted in the menu "default settings".
  • If a device contained more than 1 exercise definitions, and the device was added to a training, all exercises where added. Now a confimation is needed.
  • Search windows is added. When a letter is typed in the clientlist, the search box automatically appears and selects only the clients starting with the letters you typed.
  • Percentage of absolute values was adjusted according to male- female- and age-factors. This was unwanted and now its the percentage of the absolute maximum value of the device.
  • When the Test/1RM is performed, the percentage between set value and test value is recalculated and shown.
  • Group selection is also possible with Client result report.
  • With corrupted data on a card, the possibility to whipe the card clean is offered.
  • The client group selection, can now be given a name instead of only a number. In the menu Options, a Groups submenu can be found to define the group names.

Solved issues:
  • The percentage/force field in the exercise-information dialog sometimes showed wrong values when entered manually.
  • Pressing the ctrl-F8 button combination in any other screen then the main screen, cause the main screen to disappear.
  • Speed was indicated with Km/u in stead of Km/h.
  • In the Indication window data disappeared,  when fields where edited and when at the same time a card was inserted.
  • If a partially done training (marked blue) was set as DONE, it took a long time before the complete list was re-checked. This is solved.
  • The first time a card was read, after starting EN-Track, the client shown was not the client on the card, but the first client in the list. This is solved.
  • Dialog message "Exercise not on CC" did not show any client info. Now it does.
  • When all exercises on one device where skipped, a wrong message appeared.

It is advised to install this version
 
 

List of updates in En-Track version 6.25

 
  Functionality improvements:
  • Support of the new SCM  chipcard readers (SCR3311)
  • Rotator 2-6 device is added
Solved issues:
  • Dimensions of the Cardio Bike result values could be displayed wrong (factor 10x higher)
  • After illegal stopping EN-track, the program sometimes doesn't start up again. This is solved in v6.25

    It is strongly advised to install this update for 6.24 users !
 
 

List of updates in En-Track version 6.23

 
 
  • Several issues concerning report printing and filtering are solved
  • After reading training results from CC, the wrong data may be shown. This is the case when the treatment to which the training belongs was not the LAST treatment in the list (note: no data was lost or corrupted, only the wrong training results wwere shown) his is solved in v6.23

    It is strongly advised to install this update
 
 

List of updates in En-Track version 6.21

 
 
  • EN-Cardio Tests are implemented. Embedded version EN_Cardio Bike v3.0 must be installed.
    (nr 0413705 or higher)
    Implemented tests are: 12 min. test, 3 min. Test,  VO2Max test.
  • Through the button "Intake card" a list of all tests performed during the curent indication periode and which have a target value assigned to it.
  • Application can now be minized through the Customer and Indication window
  • Graphic representation defaults to a line-graph. Unless when only 1 test is perfomed, after which the bar-graph is shown
 
 

List of updates in En-Track version in 6.20

 
 
  • By double-clicking on an exercise in the Indication screen, the exercise-edit window is opened
  • Indication closure date added t.b.v. test rapport
  • Extended Test raports with target values added
  • USB/COM port selection upgrade
  • EN-Dynamic 1-6 added
  • Filter mechanisme extended: selection on performed training date interval and/or deferring target/perfomed values
  • French language added
  • Network configuration check during startup is updated.
 
 

List of updates in En-Track version 6.13 and 6.05

 
 
  • In several reports, the title string was not translated.
  • The date in the indicatielist was not according to the Windows date setting but had a fixed format.
  • Problem when using EN-Track with Windows XP or 2000 under standard USER priviliges es is resolved.
  • Indication name can now contain 80 characters.

      Various minor problems solved .
 
 

List of updates in En-Track version 6.12 and version 6.04

 
 
  • Network configuration check on startup added
  • Database integrity improved
  • Sometimes due to an eroneous date in a device, results were not written to the database. This is resolved.
  • Problem solved whereby testresults created via the treatment-tab sometimes get mangled when exercises with no tests are present.

    Various minor problems solved .
 
 

List of updates in En-Track version 6.11

 
 
  • Auto Numlock-On when in Clientmode, is selectable ( menu: Options->General)
  • Auto search for chipcardreader on startup is selectable (menu: Options->General)
  • Group selection possibility in General Reports (menu: Client)
  • Indication name can also be shown in list of indication (right mouse click , indication list)
  • An optional message field is added to inform the customer when all exercises where done Ok, when Client mode is activated. (Default settings , third entry line, when empty no message is shown)

    Several problems regarding the filter options are resolved.
 
 

List of updates in En-Track version 6.03

 
 
  • Auto Numlock-On when in Clientmode, is selectable ( menu: Options->General)
  • Auto search for chipcardreader on startup is selectable (menu: Options->General)


    Several minor problems are resolved.
 
     

 

date title size  
       
2007-12-12 EN-Track_User_Manual_1411755-42.zip 2.118Kb download    download_hover

 

datum title size  
       
2007-07-08 EN-TreeP_UserManual_1400755_42 436 Kb download    download_hover

 

 

datum title size  
       
2007-03-26 EN-Dynamic_Track_MDD_User_Manual_1412791_45 985Kb  download    download_hover

 

 

datum title size  
       
2007-03-26 EN_Dynamic_Compressor_maintenance_1412780_40 543Kb download    download_hover

 

 

datum title size  
       
2006-01-11 Mill_&_Mill_Track_User_Manual.zip 888Kb download    download_hover

 

 

datum title size  
       
2006-01-31 EN-Free_User_Manual_1446750_43.zip 1833Kb download    download_hover

 

 

datum title size  
       
2006-01-11 EN-Cardio_Bike_Reha_User_Manual_1413754_42.zip 5091Kb download    download_hover

 

 

datum title size  
       
2006-01-11 EN-Cardio_Bike_Reha-Addendum_1413755-40.zip 688Kb

download download_hover

 

 
datum title size  
       
2006-01-11 EN-Cardio_Crosswalker_User_Manual_1413753_42.zip 6117Kb

download download_hover

 
datum title size  
       
2006-01-11 EN-Cardio_Cruiser_User_Manual_1413752_42 5921Kb

download download_hover

 
datum title size  
       
2006-01-11 EN-Cardio_Stair_User_Manual_1413750_42.zip 15921Kb

download download_hover

 
datum title size  
       
2006-01-11 EN-Cardio_Step_User_Manual_1413751_42.zip 16048Kb

download download_hover

datum title size  
       
2006-05-09 Enraf-Nonius_Rehab_A3_Posters_DE.zip 4100Kb

download download_hover

 
datum title size  
       
2006-05-09 Enraf-Nonius_Rehab_A3_Posters_EN.zip 4100Kb

download download_hover

By default, the the libraries for creating and unpacking EN-Track container files are installed with the main EN-Track installer.

When by some reason these libraries are overwitten or removed, this update restores the correct version.

datum title size
2001-01-21 EN-Track container libraries 560Kb download download_hover

 

This command-file removes the EN-Track license.

Use with extreme care!

 

This tool may be used when system date/time was accidentally set into the future, while running EN-Track. The license module will disable further execution, since the license-periode is expired.

When you reset the date (back) to the current date, only an error message will appeare saying the Date has been tampered with.

 

In that case you have to set your PC-date into the far future (at least 2 years further) and start EN-Track. Now you wil see the message saying the EN-Track license has expired. Then you reset the date back again to the current date, and start EN-Track. Now you will see the licence request screen again and you can apply for a licence extension with the givven MID and SITE code.

 

When this procedure fails, run this tool to complete remove the license after which a new license has to be requested!

 

datum title size  
       
2008-6-16 EN-Track License Removal tool 1 kb download  download_hover

This is a stand-alone program to shutdown all active EN-Track programs remotely.  With e.g. the standard Window's, this programs allows you to close all EN-track instances zo the shared database directory can be copied to a backup device.

 

This tool can only be used with EN-Track versions 6.26 and higher. Also this tool must run on a PC with EN-Track installed and configured for the correct database. EN-Track itself does not need to be running on the PC from which this tool is used.

 

 

datum title size  
       
2007-8-16 EN-Track v6 Global shutdown tool 200 kb download  download_hover

Stand-alone tool for viewing QRP files.

 

Previews of reports can also be stored or send by e-mail as external QRP files. These files can be viewed with this tool.

 

datum title size  
       
2002-12-05 Report viewer 1.2 Mb download  download_hover

Copyright © 2018. All Rights Reserved.